Featured Articles

Selection and Application of Structural Steel Materials for Aircraft Maintenance Hangars​

图片
 Aircraft maintenance hangars , as the core facilities for aircraft inspection and repair operations, must endure long-term exposure to large-span loads, extreme weather conditions, and complex operational environments. Consequently, stringent requirements are imposed on the strength, weather resistance, and stability of the structural steel materials employed. The judicious selection of suitable steel structural materials not only ensures the hangar's safe operation but also reduces construction and maintenance costs. Based on the functional requirements of different structural components within the hangar, commonly used steel structural materials can be categorised into three main types, each playing a critical role in hangar construction. I. Primary Load-Bearing Structure: The Core Material Supporting the Hangar's ‘Skeleton’ The primary load-bearing structure forms the hangar's ‘skeleton’, bearing the hangar's own weight, aircraft parking loads, and external forces s...

Bolt Ball Testing Methods

 Bolt Ball Testing Methods

bolt ball



1, bolt ball and manufacturing bolt ball nodes need materials, its varieties, specifications, performance, etc. should comply with national product standards and design requirements.
Inspection methods: check the quality of the product qualified documents, Chinese signs and inspection reports, etc.
2Bolt ball shall not have burn, crack and crease.
Inspection method: Sample part of each specification of bolt ball, observe with 10 times magnifying glass and surface inspection.
3, bolt ball thread size and thread tolerance should be in line with the current national standard provisions.
Inspection method: check a part of each specification of the bolt ball and measure it with a standard thread gauge.
4, bolt ball diameter, roundness, adjacent two bolt hole centre line angle and other dimensions and allowable deviation should be in line with the local steel structure acceptance regulations.
5Inspection method: Sample a portion of each specification of bolt ball and check if it conforms to the specified value with calipers and indexing head gauge.