  Regulations and Methods for Considering Accidental Eccentricity Effects in Seismic Design in China, the United States and Europe 1. Regulatory Basis ● China The Code for Seismic Design of Buildings (GB 50011-2010) stipulates that accidental eccentricity must account for uncertainties in structural mass distribution, stiffness distribution, and spatial variations in seismic motion. Torsional effects shall be calculated using either static or dynamic methods. ● United States ASCE 7-22 (American Society of Civil Engineers Standard) requires consideration of accidental torsional effects, typically calculated using static methods, with verification through dynamic analysis results. ● Europe Eurocode 8 (EN 1998-1:2004) simulates the misalignment between mass centres and stiffness centres by introducing accidental eccentricity, and mandates consideration of the effects of bidirectional seismic actions . 2. Definition and Values of Random Eccentricity ● China Eccentricity: ±5% of the ...

What are the economic advantages of a space frame structure?

 

space  frame

The advantage of the space frame structure is that all the components can be spliced and installed by the factory. It only takes 45 days to 2 months for the roof of a large-scale industrial plant, and 8 to 12 months if the reinforced concrete building is used. The short project cycle greatly reduces unnecessary costs.

 

Because the weight of the space frame itself is light, under normal circumstances, it is not necessary to do pile foundations, which can save investment. According to the current domestic market price in China, the cost of light steel structure is already lower than that of reinforced concrete structure. When the span of the space frame structure is larger, the use space can be greatly increased, and its advantages are more obvious, which is also one of the competitions it relies on. big advantage.

 

Generally, the truss can be designed with a span of about 20 meters, and the supporting columns should be placed. However, the span of the space frame can be designed to 120 meters, but the steel content of the space frame does not increase much. This is also the best embodiment of the space frameeconomy. 